Podsumowanie treści

Strona 1 - VDN DualCom Mk1 & 2

Installation Manualfor CS1000 / CS1001VDN DualCom Mk1 & 2CSL Dualcom LimitedTel: 01895 474 474Fax: 01895 474 440

Strona 2 - INDEX

TroubleshootingQ. What if the VDN radio path signal has not been received by the Alarm Receiving Centre ?Check that the NVM is fitted & has be

Strona 3 - VDN DualCom Mk1 and Mk2

Troubleshooting (continued)Q. What if there appears to be random triggering of the Dualcom ?Ensure that 0 volts is common across all parts of the ala

Strona 4

Aerial SitingALWAYS do a site survey to find an area of strong signal before installation.The aerial should be mounted vertically at the point of stro

Strona 5

Aerial Siting (continued)Reliable operation is unlikely with a low signal strength. If the signal strengthLEDs, RSSI or FSSI readings show that the si

Strona 6

Inputs and Self LearningFor full Inputs connection information see Appendix 2.To aid installation, Dualcom Mk2 can learn the quiescent state of its i

Strona 7

Dualcom MountingDualcom is available as a ‘stand-alone’ or ‘plug-on’ version.The plug-on version is specifically designed for fitting to Control Panel

Strona 8

CS1052 Wireless Signal Strength MeterThe CS1052 may be used with the CS1051 Radio Test Set to align the aerial formaximum signal strength.This small h

Strona 9

ESN NumberAn ESN number uniquely identifies each Dualcom. It is the Electronic SerialNumber. It is like the ‘chassis number’ on the metal chassis of a

Strona 10

Dualcom Mk1 RegistrationThese Registration instructions are for VDN Dualcom Mk1 only.Dualcom must be ‘registered’ onto the VDN communications network

Strona 11

Dualcom Mk2 RegistrationThese Registration instructions are for VDN Dualcom Mk2 only.Whenever you apply power to the Dualcom by:a). Moving the Powe

Strona 12

INDEXProduct Description 2Part Numbers 3What to Do:Site Survey 5Installation 6System Testing 7 - 8Troubleshooting 9 - 10Help Desk & W

Strona 13

Using the CS1050 Expander BoardThe CS1050 is a plug-on board that adds an additional 8 inputs and 8 outputsto the CS1000 and CS2000 range of Dualcom u

Strona 14

Fault OutputThe fault relay contacts, C, NO and NC operates if the PSTN line is cut, the linkto the Paknet base station signal is lost, after 3 unsucc

Strona 15

Telephone Line ConnectionThere are several different types of telephone line available from service provid-ers.DigiCom, Dualcom, the CSL range of Cont

Strona 16

PSTN Line Connection OptionsDualcom’s line connection requires an analogue telephone line. For con-nection to other types of telephone line, refer to

Strona 17

PSTN Line Connection (Dualcom alone on line)Your Telecom Service Provider should be asked to supply and fit an analogueline and an NTP with terminals

Strona 18 - Mk1 only

PABX (Private Automatic Branch Exchange)A PABX is a telephone exchange in one business or building (where a dial 9 isneeded for an outside line). It c

Strona 19 - Mk2 only

ISDN (Integrated System Digital Network)The digital ISDN is a communication network where the line from the exchangeequipment and the service supplied

Strona 20

ISDN2 Line + CS0700 ConverterFig 14Home Highway, Business HighwayHome Highway or Business Highway is the marketing name for a ‘basic rate’ISDN2 line s

Strona 21

ISDN30 (Integrated System Digital Network, 30 channel)A ‘primary rate’ ISDN line can carry the equivalent of up to thirty simultaneouscalls. In UK, a

Strona 22

ADSL (Asynchronous Digital Subscriber Line) or ‘Broadband’ADSL lines are sometimes called ‘Broadband’. Many ADSL lines are Hybridlines, i.e. they carr

Strona 23

VDN DualCom Mk1 and Mk2Installation ManualDescriptionVDN Dualcom is an advanced auto-dialling Digital Communication Device forsecure alarm reporting.

Strona 24

The ‘Call Minder’ call answering ServiceSome telecom Service Providers offer a call answering service. This will answerincoming calls if the subscribe

Strona 25

System Power, Internal Battery & Power SavingDualcom Mk1 requires a supply of 12-13.8 volts DC at 230mA in standby and1.3 amps when activated. Tra

Strona 26

System Power, Internal Battery & Power Saving (continued)Dualcom Mk2 includes an internal battery that ensures continued reportingand monitoring (

Strona 27

System Power, Internal Battery & Power Saving (continued)During low-power mode, all functions continue to operate as normal but up/downloading is

Strona 28

NVM ProgrammingThe operating parameters for Dualcom, e.g. Telephone Numbers are stored inthe NVM (Non Volatile Memory). The NVM can be programmed by d

Strona 29

NVM Programming (continued)Automatic Test CallsPeriodic test calls can be sent automatically at intervals of 1 to 99 hours sincethe last call or at f

Strona 30

VDN AerialThe aerial is supplied with its bottom section fitted to the mounting bracket. Thetop section is supplied seperately in the foam packing. En

Strona 31

APPENDIX 1LED IndicationsThe Signal Strength LEDs are Red and Green. See Fig 1 & 2.The Signal Strength LEDs will give the signal strength indicati

Strona 32

APPENDIX 1LED Indications (continued)The Communication LEDs are Red and Yellow. See Fig 1.These give an indication of Power-up, Input Learning, NVM Fa

Strona 33

APPENDIX 1LED Indications (continued)VDN Path Failure Indications:The yellow Radio LED will flash to indicate a path failure.LED slow flash VDN path f

Strona 34

Part NumbersCS 1000-20 VDN Dualcom Mk2 Stand Alone (including aerial).CS 1001-20 VDN Dualcom Mk2 Plug On (including aerial).CS 1050 Expansion to 16 in

Strona 35

39APPENDIX 2Input ConnectionsThere are 8 input terminals on Dualcom (16 with the CS1050 Expander).When Dualcom is triggered the voltages on the input

Strona 36

40APPENDIX 2Input Connections (continued)Examples of ‘Positive Applied’ triggeringContact is ‘Normally Open’. Input is normally at 0 volts.When conta

Strona 37

41Examples of ‘Positive Removed’ triggeringContact is ‘Normally Closed’. Input is normally at +12 volts.When contact opens the input becomes 0 volts.E

Strona 38

42APPENDIX 3CS1001 Plug-on DualcomThe pins are mounted on the host unit, e.g. the control panel. The pins arefitted on a plastic spacer, 0.156 inche

Strona 39

fig 1.9100 9800960043APPENDIX 3CS1001 Plug-on Dualcom (continued)9100CS1001 Plug-on Locations9800 PlusPin 196009800

Strona 40

APPENDIX 4SpecificationModels CS1000-20 Stand Alone and CS1001-20 Plug OnDimension (h x w x d) 125 x 172 x 62 mmWeight 800 grams (includes internal b

Strona 41

APPENDIX 5European PSTN ApprovalThe CS1000 range of Dualcom products meet the requirements of the EU PSTNstandard CTR21 and is approved for conn

Strona 42

APPENDIX 6Glossary of TermsADSL Asynchronous Digital Subscriber LineA ‘wideband’ digital communication service from a network provider to asubs

Strona 43

APPENDIX 6Glossary of Terms (continued)Digital PSTN Digital Public Switched Telephone Network.The digital national telephone system. Service is

Strona 44 - 9100 9800

APPENDIX 6Glossary of Terms (continued)ISDN 2 2 Channel ISDNAn ISDN communication service where two simultaneous channels may beused. Each cha

Strona 45

AerialConnectorBattery CoverScrewFig 2Battery CoverRed & Green Signal Strength LEDsInternalBatterySocket Red & YellowCommunication LED

Strona 46

APPENDIX 6Glossary of Terms (continued)VDN Vodafone Data Network (Paknet)A private communication system operated by Vodafone in UK for users th

Strona 47

Site SurveyIt is strongly recommended that a Site Survey is conducted prior to in-stallation of a VDN Dualcom to confirm that adequate VDN signal stre

Strona 48

Installation1. Assemble the aerial by screwing the metal rod and the flexible aerial into themounting bracket. Site the aerial vertically at the poin

Strona 49

System TestingEnsure you have informed your Alarm Receiving Centre that you are readyto test your Dualcom Product.1. Reconnect the mains supply to th

Strona 50

8System Testing (continued)6. If you are using the Alarm Abort feature, set the Alarm Panel, initiate analarm condition and (If the alarm system incor